Point Source Plan & Section Noise Map

ISO 9613-2:1996 (KS I ISO 9613-2) · octave bands 63 Hz–8 kHz · grid-node input · barrier top / lateral diffraction · wall reflections

Input tools

Area & grid

Propagation

G: 0 = paving, water, concrete; 1 = grass, farmland. C₀ = 0 gives downwind LAT(DW); C₀ > 0 gives long-term LAT(LT).

File

––
Symbols: S sound source · B noise barrier · W building wall / fence · GZ ground zone · Re receiver
Cross-section→z bottom / top (m)
––

Selected item

Use Select and click a source S, barrier B, ground zone GZ or receiver Re to edit it.

Receiver results LAeq dB(A)

Verification (vs. standard)

Method: LfT(DW) = LW + Dc − (Adiv + Aatm + Agr + Abar) per octave band, then A-weighted sum (Eq. 3–5). Ground: general method (Eq. 9, Table 3). Barrier top Abar = Dz − Agr (Eq. 12), lateral Abar = Dz (Eq. 13); two or more barriers use the two most effective as double diffraction (Eq. 15, 17). Reflections by image sources (Eq. 19, 20). Single A-weighted sources use the §7.3.2 simplified method (500 Hz attenuation, Eq. 10, 11).